0417 557 719

Most Common Silos Built

Cyclone Width of silo Tiers High Volume Capacity Fans Fill Auger
Silo Model Feet [Meters] Cu Met Tonnes Std Estimate
Wheat Feet [Meters]
3622 36 Feet [10.98] 6 728 604 60-65 [21]
3626 7 833 691 3Kw 65-70 [21]
3629 8 938 779 3 Kw 70-75 [22]
3633 9 1043 866 4 Kw 75-80 [23]
3637 10 1148 953 4 Kw 80-85 [25]
3640 11 1253 1040 85-90 [26]
4226 42 Feet [12.8] 7 1157 960 4 Kw 75-80 [23]
4229 Single Fan 8 1300 1079 1 x 4 Kw
4229 Twin fan * 8 1300 1079 2 x 3 Kw 80-85 [25]
4233 Single fan 9 1442 1197 1 x 4 Kw
4233 Twin Fan * 9 1442 1197 2 x 3 Kw 80-85 [25]
4237 Single Fan 10 1585 1316 1 x 4 Kw
4237 Twin Fan* 10 1585 1316 2 x 3 Kw 85-90 [26]
4826 Twin fan 48 Feet [14.63] 7 1540 1278 2 x 3 Kw 80-85 [25]
4829 Twin fan 8 1727 1433 2 x 3 Kw 85-90 [26]
4833 Twin fan 9 1913 1588 2 x 4 Kw 90-95 [28]
4837 Twin fan 10 2100 1743 2 x 4 Kw 95-100 [30]
Notes:
Silo Sizes: Expressed in Feet. Diameter x Height
Capacity in Tonnes: Based on average wheat density of 830Kg/Cu Met.
Aeration Fans: Common sizes fitted as shown. Aim is for a minimum of 2 litres/tonne /second when full.
* 42 Feet silos will require 2 fans to achieve new recommended aeration flows. Many growers achieve quality out comes with only one aeartion fan opertaed correctly.
Higher aeration flow silos are now comonly built. Aeration parameters are a descision to be made when planning.
Vents: Number fitted is matched to aeration fan delivery.
Type fitted: Ground operated, high flow & sealable for fumigation.
Unloaders:
250 mm diameter commonly fitted to 42 & 48 Ft
300 Mm fitted where high delivery flows are required
Fill Auger Estimate: A length that will allow a low fill angle for high flow and reduced break down. Expressed in Feet [Meters]

Smaller Silos Available

Cyclone Width of silo Tiers High Volume Capacity Fans Fill Auger
Silo Model Feet [Meters] Cu Met Tonnes Std Estimate
Wheat Feet [Meters]
2429 24 Feet [7.32] 8 402 334 60-65 [20M]
2433 9 449 373 2 Kw 65-70 [21M]
2437 10 496 412 65-70 [21M]
3026 30 Feet [9.15] 7 567 471 60-65 [18M]
3029 8 640 531 2Kw 65-70 [20M]
3033 9 713 592 3 Kw 70-75 [22M]
3037 10 786 652 3 Kw 75-80 [23M]
3040 11 859 713 75-80 [24M]
Notes:
Silo Sizes: Expressed in Feet as Diameter – Height
Capacity in Tonnes: Based on average wheat density of 830Kg/Cu Met.
Aeration Fans: Common sizes fitted as shown. Aim is for minimum of 2 litres/tonne /second when silo is full.
Higher aeration flow silos are now comonly built. Aeration parameters are a descision to be made when planning.
Vents: Number fitted is matched to aeration fan delivery.
Unloaders:
200mm diameter commonly fitted to 24,30 & 36 Ft silos
250 mm diameter fitted if higher output flows are required.
Fill Auger Estimate: A length that will allow a low fill angle for high flow and reduced break down. Expressed in Feet [ Meters]